All studies
Respiratory · EHR · US

Makgoeng 2026

Asthma and COPD

QBA performedITTSuperiorityAcademia, Industry2/5 disclosures
Comparisons
2
In the analysis
1
1 withheld
Target trials
2
Emulations reported
2
2 treatments

Comparisons

2 shown
Randomized trialEmulation
Outcome & target trialTrial vs emulationOn a shared scaleAgreement
Annualized moderate or severe asthma exacerbation rate
vs QUEST·RR·Efficacy
0.540.43–0.68
0.480.44–0.52
overlapPartial alignment-0.95 SE apart
Annualized moderate or severe COPD exacerbation rate
vs BOREAS·RR·Efficacy
0.770.60–0.99
0.510.24–0.79
not pooledPartial alignment

Design and methods

Estimand
ITT
Design hypothesis
Superiority
Matching / weighting
Augmented IPTW
Analysis method
Doubly robust weighted rate model
Missing data
Not reported
DAG
No
QBA
Yes

Data and sample

Data type
EHR
Data sources
1
Geography
US
Eligible sample
COPD 4333; asthma 115761
Emulations
2
Treatments compared
2

Transparency

2/5
Protocol
No pre-registration
Preprint
No preprint
Data availability
Unavailable
Code availability
Unavailable
Conflicts of interest
Declared: Industry
COI institutions
Pfizer and relationships listed in the report
Funding
Declared: Private
Funders
Pfizer

The 0-5 count records which disclosures are present. It is not a quality score: a data link does not establish that the data are reusable.

Provenance

Review key
2026_Makgoeng_AsthmaCOPD
DOI
10.3389/fmed.2026.1863026
Affiliations
Pfizer and collaborating academic institutions
Sector
Academia, Industry
Target trials (study level)
BOREAS; QUEST
Registration
NCT03930732; NCT02414854